Real-Time Pack View
Pressing the Packs button on the front panel of the Control Unit or pressing Menu and navigating to Radio Pack Settings displays a list of all connected Radio Packs (RP), including detail of each RP’s model, frequency band, and mode.
CrewWare's RP display is a real-time view of each Radio Pack (RP) paired to the system.
- The top portion of the window (or "Active panel") displays RPs in operation with “Live” connection status. (These RPs remain in the "Active" panel until CrewWare has been disconnected or closed, regardless of whether the RP is powered off.)
- The bottom portion of the window (or "Inactive panel") displays RPs that are paired to the system, but not yet logged in.
See Real-Time Pack View Pane (“Tile” View) for information about what is displayed on each RP icon. You may also hover the mouse over an individual RP icon to view additional information such as Profile Name, Device ID, Model Number, Operational Mode, etc. Double-click on an individual RP icon to access its Device Management detail view. Right-click on an individual RP in order to modify the list display, enable the Mic Kill option, or unpair the RP.
The Active and Inactive panels can be customized by right-clicking: In the menu that displays, hover over the Organize By option, and then choose RT (ascending or descending order) to display the RP icons under RT headers. Choose Group (ascending or descending order) to display the RP icons under Group headers (with color settings determined from the Group Management Tab.)
Pack Display Overview |
|
Label |
Field/Function |
A |
RP “Glow” Indicator – When the RP icon is illuminated green, that RP is active on the system. Red means the RP has a low battery. Blue means the RP is logged out of the CU. Gray means that RP is powered off. |
B |
RP Name (long name) |
C |
RT Name (long name) |
D | Profile Name (long name) |
E |
Volume Knob/Talk Button Indicators – Displays indicators A–D or A–B (depending on RP model), and illuminates individual indicators green when their Talk function is active. Indicators illuminate light blue when the button has been assigned a conference and the user is currently listening to that conference. Indicators illuminate gray to indicate that no conference has been assigned to that button. Displays a volume level indicator surrounding the individual indicator. In the “tile” view, an “I” will display over the indicator to represent ISO when the button is pressed. On the CRP-12, displays a dedicated TALK button indicator. |
F |
Function Button Indicators – Display indicators for F1 and F2, which each illuminate green when their function is active. |
G | High Density Indicator - Indicates that the RP is using a profile set to High Density Operational Mode. |
H |
Battery Running Time and Level |
I |
Link Quality – Provides a diagnostic measurement of actual packet transmission from RP to RT and vice versa. The outlined LQ represents the RT’s Receive LQ. The other number represents the RP’s Receive LQ. Note: When using a High Density profile (indicated by the "H"), the outlined LQ display will be blank until a talk button is pushed.
|
J |
Radio Signal Strength Indicator (RSSI) |
K |
RP Frequency |
Alternate Real-Time Pack Views
Real-Time Pack View Pane (“Device Detail View”)
Real-Time Pack View Pane (“Icon” View)